Types | Accessories | Software |
Wavelength range | 350-2500 nm |
Resolution | 3nm@700 nm 6nm@1400/2100nm |
Scanning time | 100 miliseconds |
Signal-to-noise ratio | VNIR: 9,000:1 @ 700 nm SWIR 1: 9,000:1 @ 1400 nm SWIR 2: 4,000:1 @ 2100 nm |
Stray light | VNIR: 5000:1 (0.02%) NIR: 10,000:1 (0.01%) |
Wavelength reproducibility | 0.1nm |
Wavelength accuracy | 0.5nm |
Channels | 2151 |
VNIR detector | (350-1000 nm) 512 element silicon array |
SWIR 1 & 2 detectors | (1000-1800 nm) & (1800-2500 nm) - Graded Index InGaAs Photodiode, TE Cooled |
Certification and Approvals | CE certified: EN61010-1:2001 2nd Edition EU Directive: 2006/95/EC, 2004/108/EC NIST traceable calibration WEEE Compliance |
Communications | Wired: 10/100 Base T Ethernet port with Ethernet cross-over cable Wireless: 802.11g wireless card |
Dimensions | (H x W x D) 12.7 x 36.8 x 29.2 cm (5 x 14.5 x 11.5 in) |
Weight | 5.44 kg (12 lbs) |
Battery weight | 1.2 kg (2.7 lbs) |
Battery run time | Approximately 6 hours (without lamps or accessories) |
Operating temperature |
0 to 40° C (32 to 104° F) |
Storage temperature |
-15 to 45° C (5 to 113° F) |
Input power | AC/DC switching power supply and a sealed lead-acid gel cell battery |
AC input | 90-240 VAC, 50/60 Hz |
DC input | 12 VDC, 60 W |
Auxiliary port power | Output, +12 VDC, 27 Watt (max) |
Software |
RS3™ and Indigo Pro spectral acquisition software. Compatibility with The Spectral Geologist and SpecMin, Seamless interface with ENVI®, ASD ViewSpec™ Pro for post processing, optional Indico® Pro |
Portability | Rugged instrument transportation case; optional customized backpack with soft-sided travel bag |
Warranty | One year full warranty including expert customer support |
Computer | Windows® 7 64-bit laptop (instrument controller) |
Ergonomic Pro-Pack BackpackThe ASD Ergonomic Pro-Pack Backpack takes field portability to a higher level for FieldSpec, LabSpec, and TerraSpec customers requiring the ultimate in portability. |
|
Fiber Optic CablesFiber optic cables are available in a variety of lengths and styles for different application requirements. |
|
Fiber Checker MagnifiersThis ASD proprietary software and hardware diagnostic tool was developed so that people using ASD spectrometers can check the internal glass fibers built into the fiber optics. The Fiber Checker allows the user to reverse illuminate the VNIR, SWIR 1 and SWIR 2 regions individually or all together. By attaching the Optical Magnifier and counting the illuminated fibers, the user can then confirm that there are no broken fibers internally on the fiber optic cable |
|
Hi-Brite Muglight (opsiyonel)Designed for analysis of raw materials requiring reflectance and absorbance measurements of minerals and some inorganic material applications requiring a higher intensity light. |
|
Hi-Brite Contact ProbeFor non-destructive contact measurements and characterization of mineral and ore samples |
|
Referance PanelsReference panels are available in calibrated and non-calibrated diffuse white and gray, in varying sizes and reflectance levels, including encapsulated gray scale (NIST/NRC traceable) wavelength and USP standards for USP 1119. |
|
goLab Mobile Work StationThe goLab™ Mobile Work Station acts as a wheeled carrier for streamlined transport between locations, and then quickly unfolds to support all your sampling needs “right on the spot”. For use with ASD’s full-sized portable spectrometers and spectroradiometers. |